FOX CHANTIER FB12 is a modified acrylic copolymer-based, high-opacity, matt-finish elastic topcoat interior wall paint. Its odourless and flexible nature makes it suitable for safe application on interior plaster and concrete surfaces.
Colour Palette
Packaging
Product Description
FOX CHANTIER FB12 is an acrylic copolymer emulsion-based, high-opacity, matt-finish elastic topcoat interior wall paint. Thanks to its water-based formulation, the product is odourless and flexible, and can be easily applied to mineral surfaces such as interior plaster and concrete. Its high density (1.56±0.05 kg/lt) and 60% solid content provide strong coverage. With a touch-dry time of 15±5 minutes and a surface-dry time of 60±5 minutes, the product offers a practical application process with a recoat interval of 4–6 hours. FOX CHANTIER FB12, with a service temperature between +5°C and +30°C, provides a durable interior wall coating with resistance to blistering and peeling in humid environments.
Advantages
- High Opacity
- Non-yellowing
- Dust and dirt repellent
- Odourless and flexible
- High resistance to scuff marks
- Durable
- Prevents blistering and peeling in humid environments
Usage Areas
- Interior plaster surfaces
- Interior concrete surfaces
Application Steps
- 1
Surface Preparation
The application surface must be sound, dry, load-bearing, dust-free and clean. It must be free of loose particles and residues of oil, grease, rust and paraffin. Uneven surfaces should be filled with FOX SILK MORTAR FC125. Freshly plastered surfaces (lime-free, made with FOX MIXPLUS FM201 or FOX BINDER FM125) and reinforced concrete surfaces must have completed a 28-day curing period.
- 2
Mixing
FOX CHANTIER FB12 must be thoroughly mixed with an electric mixer at 400–600 rpm before use.
- 3
Thinning
A maximum of 10% water may be added to FOX CHANTIER FB12. For large-area projects, all products must be thinned at the same ratio to avoid shade differences.
- 4
Application on Gypsum Plaster Surfaces
Since gypsum plaster is a dusty and absorbent material, FOX DECODUR PRIMER primer must be applied before proceeding with paint and filler application. After a minimum of 12 hours, FOX CHANTIER FB12 can be applied in at least two coats.
- 5
Application on Raw Plastered Surfaces
Before proceeding with paint application, adhesive tape should be pressed firmly onto the surface and then pulled off; if dense sand particles remain on the tape, the surface has a loose texture and must be sanded with abrasive mosaic stones. After sanding, one coat (two coats if necessary) of FOX DECODUR PRIMER primer is applied, followed by at least two coats of FOX CHANTIER FB12.
- 6
Application on Water-Based Previously Painted and Filled Surfaces
If plaster is to be applied over old paint, the surface must be scored densely. Once the substrate preparation is complete and if the old paint is glossy, it should be sanded and dusted with a damp cloth, then one coat of FOX DECODUR PRIMER primer is applied. After priming, at least two coats of FOX CHANTIER FB12 can be applied.
- 7
Application on Solvent-Based Previously Painted Surfaces
Once the substrate preparation is complete and the surface has been sanded and dusted with a damp cloth, one coat of FOX UNIPRIMER FL555 is applied. After priming, at least two coats of FOX CHANTIER FB12 can be applied.
- 8
Tool and Equipment Cleaning
Tools and equipment used during application must be cleaned with water after use. Once FOX CHANTIER FB12 has hardened, it can only be removed from surfaces mechanically.
Application temperature must not fall below +5°C. FOX CHANTIER FB12 freezes at temperatures below 0°C.
The application surface must be sound, dry, load-bearing, dust-free and clean. It must be free of loose particles and residues of oil, grease, rust and paraffin.
Freshly plastered and reinforced concrete surfaces must have completed a 28-day curing period.
A minimum recoat interval of 4–6 hours must be observed between coats.
For large-area interior wall projects, all products must be diluted at the same ratio to avoid shade differences.
The product may be diluted with water by a maximum of 10%. Exceeding this ratio is not recommended.
Opened containers must be tightly resealed, stored under appropriate conditions and used within one week.
When stored at room temperature, away from direct sunlight, between +5°C and +30°C, the shelf life is 12 months from the date of manufacture.
For short-term storage, pallets may be stacked no more than 3 high; for long-term storage, pallets must not be stacked on top of one another.
Storage and application areas must be ventilated. Work clothing, protective gloves, goggles and a mask must be worn during application.
The product must not come into contact with skin or eyes. In case of contact, wash immediately with plenty of water and soap; if swallowed, seek medical attention immediately.
Must be stored out of reach of children. Food and beverages must not be brought into application areas.
For detailed safety information, refer to the Material Safety Data Sheet (MSDS).