FOX EPOTHANE® BASECOAT CLEAR is an epoxy resin-based, two-component, solvent-free, self-levelling clear decorative floor coating. With its high chemical and mechanical resistance, it is reliably used in airports, hospitals, shopping centres and all areas requiring hygiene.

Colour Palette

Clear

Packaging

17,65 kg
TDS

Product Description

FOX EPOTHANE® BASECOAT CLEAR is an epoxy resin-based, two-component, high chemical resistance, solvent-free, self-levelling clear decorative floor coating. The recommended application thickness is between 1.0 mm and 2.0 mm. With a density of 1.1 gr/cm³, the product achieves a 7-day compressive strength of 60 N/mm² and a flexural tensile strength of 30 N/mm². Adhesion strength to concrete is >1.5 N/mm² and the total solid content is 100%. Pot life at +23°C is 1 hour. Prior to application, surface preparation with a suitable FOX EPOTHANE® series primer is mandatory.

Advantages

  • High chemical and mechanical resistance.
  • Easy to maintain and clean.
  • Flowable consistency.
  • Provides hygienic environments.
  • Liquid-impermeable.
  • Delivers a high-gloss topcoat finish.
  • High adhesion strength.
PropertyValue
Density1,1 gr/cm³
ColourClear
Compressive Strength (7 days)60 N/mm²
Flexural Tensile Strength (7 days)30 N/mm²
Adhesion Strength (to Concrete)>1,5 N/mm²
Total Solid Content%100
ThinningNot thinned
Substrate Application Temperature+10°C / +30°C
Shore D Hardness (7 days)84
Pot Life1 hour
Recommended Thickness1,0 mm - 2,0 mm
Recoat Time (+10°C)Min. 26 - Max. 32 hours
Recoat Time (+20°C)Min. 18 - Max. 24 hours
Recoat Time (+30°C)Min. 12 - Max. 16 hours
Open to Foot Traffic (+10°C)30 hours
Open to Foot Traffic (+20°C)26 hours
Open to Foot Traffic (+30°C)18 hours
Open to Light Traffic (+10°C)4 days
Open to Light Traffic (+20°C)3 days
Open to Light Traffic (+30°C)2 days
Full Cure (+10°C)10 days
Full Cure (+20°C and +30°C)7 days
Shelf Life12 months (from date of manufacture)
Storage Temperature+5°C / +30°C

Usage Areas

  • Areas where decorative flooring is desired
  • Areas requiring chemical and mechanical resistance
  • Airports
  • Galleries
  • Shopping centres
  • Supermarkets
  • Shops and showrooms
  • Hotels
  • Hospitals and nursing homes
  • Clinics
  • Schools and nurseries
  • Areas where hygiene is required

Application Steps

  1. 1

    Surface Preparation

    Concrete substrates must be opened to a porous surface by removing the cement laitance using abrasive equipment such as shot blasting, milling or diamond grinding. Weak concrete sections must be removed, small voids and holes must be fully opened, and the resulting dust must be cleaned with an industrial vacuum. For filling voids and levelling the surface, a mortar prepared by mixing 60–70 AFS (0.1–0.3 mm) quartz sand with FOX EPOTHANE® PRIMER series primer should be used.

  2. 2

    Surface Quality Control

    Concrete compressive strength must be at least 25 N/mm², tensile strength at least 1.5 N/mm², moisture content a maximum of 4%, and substrate temperature a minimum of +8°C. The substrate temperature must be at least +3°C above the dew point. The surface must be clean, dry and free from foreign matter such as oil, grease, old coatings and curing compounds.

  3. 3

    Priming

    Surfaces to receive FOX EPOTHANE® BASECOAT CLEAR must be primed in advance with a suitable FOX EPOTHANE® series primer. The substrate temperature must not fall below a minimum of +8°C. The coating must be applied over the primer within the specified application window.

  4. 4

    Mixing

    After component B has been fully added to component A, mix with an electric mixer at 300–400 rpm using an epoxy/polyurethane resin mixing paddle for at least 3 minutes until a homogeneous mixture is obtained. Avoid excessive mixing to prevent air entrainment.

  5. 5

    Coating Application

    FOX EPOTHANE® BASECOAT CLEAR is poured onto the surface and spread evenly with a notched trowel. Once the coating reaches the appropriate consistency, a spike roller must be applied to remove air. If the spike roller application is delayed, marks may remain on the surface.

  6. 6

    Tool and Equipment Cleaning

    After application, tools and equipment must be cleaned with solvent or epoxy thinner. Once the product has cured, it can only be removed from the surface by mechanical means.

Critical

Surface temperature, ambient temperature and material temperature must be a minimum of +10°C and a maximum of +30°C.

Critical

The substrate temperature must be at least +3°C above the dew point; otherwise condensation and water vapour will damage the coating.

Critical

After application is complete, the coating must be protected from direct water contact for at least 24 hours. In the event of water contact, softening and blistering may occur on the coating; the coating must be completely removed and reapplied.

Critical

Substrate moisture content must be below 4%; there must be no rising moisture according to ASTM.

Critical

Relative humidity must be a maximum of 80%.

Critical

Mixing must be carried out with an electric mixer at 300–400 rpm using an epoxy/polyurethane resin mixing paddle; if the specified paddle is not used, air bubbles may form in the coating.

Important

After component B has been fully added to component A, mixing must continue for at least 3 minutes until a homogeneous mixture is obtained; avoid over-mixing to prevent air entrainment.

Important

Concrete surfaces to be coated with epoxy/polyurethane must be at least 3 weeks old prior to application.

Important

If the spike roller application is delayed, spike roller marks may remain on the surface.

Important

Materials to be used should be brought to the application site 1–2 days in advance and allowed to acclimatise to ambient conditions.

Important

In cold weather, packaging should be conditioned at +20°C – +25°C to improve workability before use.

Important

Rain, dust, wind, animals and insects must be prevented from accessing the fresh coating.

Important

The product must be stored between +5°C and +30°C, away from direct sunlight, in a cool and dry environment, protected from frost. Shelf life is 12 months from the date of manufacture.

Important

For short-term storage, pallets must not be stacked more than 3 high; for long-term storage, pallets must not be stacked on top of each other.

Critical

Open flames near storage and application areas are dangerous; areas must be ventilated.

Critical

Protective clothing, gloves, goggles and a mask must be worn during application. Avoid contact with skin and eyes; in case of contact, wash thoroughly with plenty of water and soap; if swallowed, seek medical attention immediately.

Information

The product does not contain volatile organic compounds (VOC/solvents).

Information

Technical values are given for +23°C and 50% relative humidity; higher temperatures shorten the times, lower temperatures extend them.