FOX DOMINO® AC SEALER FD796 is a single-component, water-based, solvent-free, acrylic-based protective topcoat material developed for preventing dusting, providing water impermeability, and achieving a glossy appearance on all types of concrete and cement-based floors.

Colour Palette

Opaque White

Packaging

5 kg
TDS

Product Description

FOX DOMINO® AC SEALER FD796 is a ready-to-use, single-component, liquid acrylic copolymer dispersion-based topcoat protective material. It is applied on all types of old or new concrete, exposed aggregate site concrete, cement-based floor coverings, terrazzo, and cement-based pool coatings. The glossy film layer it forms acts as a polish; it increases abrasion resistance, prevents dusting, and provides water impermeability. As it contains no solvent, application safety is high. It is easily applied by roller or brush; two or more coats can be applied depending on the condition of the surface. Consumption for 2 coats is between 100–200 g/m².

Advantages

  • Increases abrasion resistance and prevents dusting
  • Provides water impermeability and prevents cracks that may occur due to freezing
  • Used as a polish thanks to the glossy film layer it forms
  • Preserves the natural appearance of the applied surface
  • Easy to apply and use
  • Achieves a smooth surface that is extremely easy to clean
  • Solvent-free
PropertyValue
Material CompositionLiquid acrylic copolymer dispersion
Density1 gr/cm³
pH8,20
Solid Content%18
ColourOpaque White
Working Time35-45 min
Drying Time60 min
Application Surface Temperature+10°C / +25°C
2nd Coat Application Time4 hours
ThinningNot thinned
Shelf Life12 months (from date of manufacture)
Storage Temperature+10°C / +30°C

Usage Areas

  • On all types of old or new concrete and exposed aggregate site concrete
  • On cement-based floor coverings and terrazzo
  • On floors and walls where a glossy appearance is desired
  • On cement-based pool coatings

Application Areas

Application Steps

  1. 1

    Surface Preparation

    If applying to an existing cement-based floor, cracks are repaired and loose particles on the surface are removed. The surface is sanded and swept with an industrial vacuum machine. If the surface is a newly applied cement-based coating with no existing cracks, application can proceed directly after sanding.

  2. 2

    Verification of Application Conditions

    Confirm that the surface, material, and ambient temperature are between +10°C and +25°C. Check that the surface moisture content is a maximum of 4%, relative air humidity is a maximum of 80%, and the floor temperature is at least +3°C above the dew point. For new concrete, a minimum of 28 days of curing must have been completed.

  3. 3

    Mixing

    FOX DOMINO® AC SEALER FD796 is ready to use; no mixing or thinning is required.

  4. 4

    Application

    The product is applied to the surface by roller or brush. The application density should be adjusted according to the condition of the surface. Two or more coats can be applied if necessary; a minimum of 4 hours must be allowed between coats.

  5. 5

    Tool and Equipment Cleaning

    After application, tools and equipment used must be cleaned with solvent.

Critical

When applying to freshly cast concrete, the concrete must have completed a minimum of 28 days of curing.

Critical

The temperature of the surface, material, and ambient environment must be between +10°C and +25°C.

Critical

The moisture content at a concrete depth of 2 cm must be below 4%. Test methods: C-Aquameter, CM-Device, Darr Method.

Critical

There must be no rising moisture according to ASTM. (Polyethylene sheet test).

Important

Relative air humidity must be a maximum of 80%.

Critical

Beware of dew point and condensation! Dew formation and water vapour condensation on uncoated or freshly coated surfaces will damage the coating. The floor temperature must be at least +3°C above the dew point.

Important

For the second coat application, a minimum of 4 hours must be allowed after the first coat has dried.

Important

The product must not be thinned.

Important

The product must be stored in its original unopened packaging, in a cool and dry environment, protected from frost, between +10°C and +30°C. Shelf life is 12 months from the date of manufacture.

Critical

It is dangerous to approach storage and application areas with open flame. Work clothing, protective gloves, goggles, and a mask must be worn during application. Avoid contact with skin and eyes; in case of contact, wash thoroughly with plenty of water and soap. In case of ingestion, consult a doctor immediately. Store out of reach of children.